F300S/F300SQ
Ultraviolet Lamp System
Installation, Operation, and Maintenance
Manual No. 509252 Rev R 3/04
FUSION UV SYSTEMS, INC.
910 Clopper Road
Gaithersburg, MD 20878-1357 USA
(301) 527-2660 • FAX (301) 527-2661
Vista de página 0
1 2 3 4 5 6 ... 153 154

Resumo do Conteúdo

Página 1 - Ultraviolet Lamp System

F300S/F300SQ Ultraviolet Lamp SystemInstallation, Operation, and MaintenanceManual No. 509252 Rev R 3/04FUSION UV SYSTEMS, INC.910 Clopper RoadGaither

Página 2

10 F300S/F300SQ Ultraviolet Lamp SystemP300M/P300MT Power Supply Parts List . . . . . . . . . . . . . . . . . . . 144P300MQ Quick Restart Option Par

Página 3 - Lamp System

100 F300S/F300SQ Ultraviolet Lamp System4. Remove the extrusions. While holding the extrusion inside the casting, remove the four screws securing the

Página 4

Installation, Operation, and Maintenance Manual # 509252 Rev R 101Figure 39. I310M/I311M Irradiator Component Location (Scatter View)Direct View Phot

Página 5 - Table Of Contents

102 F300S/F300SQ Ultraviolet Lamp System6. Replace the photoresistor and UV filter lens assembly.7. Reinstall the housing.Figure 40. I310M-D/I311M-D I

Página 6

Installation, Operation, and Maintenance Manual # 509252 Rev R 103Figure 41. Photoresistor Assembly for Direct View (I300M)Filament Transformer Remov

Página 7

104 F300S/F300SQ Ultraviolet Lamp SystemMagnetron Removal/Replacement1. Remove the irradiator housing as described previously.2. Disconnect the filame

Página 8

Installation, Operation, and Maintenance Manual # 509252 Rev R 105Air Pressure VerificationTo test air pressure inside the irradiator, remove one cov

Página 9

106 F300S/F300SQ Ultraviolet Lamp System2. Pull the silicone tubing off the low pressure port of the switch.3. Disconnect the two electrical leads fro

Página 10

Installation, Operation, and Maintenance Manual # 509252 Rev R 107Test Point VoltagesControl Card Removal/ReplacementThis unit must be disconnected a

Página 11 - Introduction

108 F300S/F300SQ Ultraviolet Lamp SystemDiode TestAn ohmmeter can be used to check for a shorted or open capacitor. (Isolate the component before maki

Página 12 - Document Conventions

Installation, Operation, and Maintenance Manual # 509252 Rev R 109Figure 44. P300M/P300MQ Component Identification

Página 13 - Icon Usage

Installation, Operation, and Maintenance Manual # 509252 Rev R 11IntroductionThis manual is designed to be used, not set aside until problems occur.

Página 14

110 F300S/F300SQ Ultraviolet Lamp SystemCapacitor TestCAUTION: An ohmmeter can be used to check for a shorted or open capacitor. (Isolate the componen

Página 15 - System Description

Installation, Operation, and Maintenance Manual # 509252 Rev R 1111. Disconnect all power, discharge the high voltage capacitors, and disconnect all

Página 16

112 F300S/F300SQ Ultraviolet Lamp SystemNOTE: When colors are indicated, the first is the wire color and the second is the stripe color. P300MT Power

Página 17 - System Components

Installation, Operation, and Maintenance Manual # 509252 Rev R 113Test Point Voltages.Control Card Removal/ReplacementThis unit must be returned to F

Página 18

114 F300S/F300SQ Ultraviolet Lamp System3. Remove all connectors.4. Remove three screws at the top of the card. Slide the card approximately an inch a

Página 19 - Lamp Bulb

Installation, Operation, and Maintenance Manual # 509252 Rev R 115Capacitor TestThe ohmmeter should have a minimum 6V battery, and should be set on t

Página 20 - System Interconnections

116 F300S/F300SQ Ultraviolet Lamp System2. With an ohmmeter set on the highest scale, measure the resistance between the two outside capacitor termina

Página 21 - Warranty Policy

Installation, Operation, and Maintenance Manual # 509252 Rev R 117NOTE: When colors are indicated, the first is the wire color and the second is the

Página 22 - Shipping Instructions

118 F300S/F300SQ Ultraviolet Lamp SystemThe filters pull out easily. New filters should be tucked in at the edges. The white side belongs outside, so

Página 23 - RF Detectors

Installation, Operation, and Maintenance Manual # 509252 Rev R 119Figure 48. Blower ComponentsBlower CoverGroundConnectionsCapacitor HousingJ11Ground

Página 24

12 F300S/F300SQ Ultraviolet Lamp System• Appendix C, “Outline Drawings,” contains drawings that provide overview details for general reference for Fus

Página 25 - Chapter 1. Safety

120 F300S/F300SQ Ultraviolet Lamp SystemFigure 49. J11 Connections8. Connect the replacement J11 connector to the chassis. The black and white leads f

Página 26 - Microwave Radiation

Installation, Operation, and Maintenance Manual # 509252 Rev R 121Appendix A. SpecificationsThis appendix outlines the various characteristics of ma

Página 27 - Radio Interference

Specifications122 F300S/F300SQ Ultraviolet Lamp SystemFront Panel ControlsSystem Power ON/OFF - 2 position switchLamp Control ON/STANDBY/OFF - 3 illum

Página 28 - Temperature

Installation, Operation, and Maintenance Manual # 509252 Rev R 123IrradiatorsIrradiatorsTable 26 lists the various Fusion UV Systems Irradiator model

Página 29 - UV Curable Materials

Specifications124 F300S/F300SQ Ultraviolet Lamp SystemExterior: Brushed aluminum.Mechanical (without Blower):Length: 260.4 mm (10.25")Height: 276

Página 30

Installation, Operation, and Maintenance Manual # 509252 Rev R 125IrradiatorsSystem Agency ApprovalsTable 28 lists the quality standards and agency r

Página 31 - Unpacking and Inspection

Specifications126 F300S/F300SQ Ultraviolet Lamp System

Página 32 - The four or six cover screws

Installation, Operation, and Maintenance Manual # 509252 Rev R 127Appendix B. Cables and ConnectorsThis appendix provides information on the interco

Página 33 - Irradiator Mounting

Cables and Connectors128 F300S/F300SQ Ultraviolet Lamp SystemSystem Connector Contact KitsEach kit includes pins and contacts for referenced connectio

Página 34 - UV Light Shielding

Installation, Operation, and Maintenance Manual # 509252 Rev R 129Appendix C. Outline DrawingsThe drawings in this appendix provide overview details

Página 35 - RF Detector Mounting

Installation, Operation, and Maintenance Manual # 509252 Rev R 13DANGER: Danger indications identify conditions where death or permanent injury to pe

Página 36 - Quartz Plates

Outline Drawings130 F300S/F300SQ Ultraviolet Lamp SystemFigure 50. P300M/P300MQ Power Supply Dimensions and Clearances

Página 37

Installation, Operation, and Maintenance Manual # 509252 Rev R 131Figure 51. P300MT Power Supply Dimensions and Clearances

Página 38

Outline Drawings132 F300S/F300SQ Ultraviolet Lamp SystemFigure 52. I300M Irradiator Dimensions3. Air pressure measured at lamp inlet 695Pa (2.8"H

Página 39 - Chapter 3. Electrical System

Installation, Operation, and Maintenance Manual # 509252 Rev R 133Figure 53. I300MB Irradiator DimensionsNotes:1. Dimensions in mm (in)2. Air pressur

Página 40 - HIGH VOLTAGE CABLE

Outline Drawings134 F300S/F300SQ Ultraviolet Lamp SystemFigure 54. I310M/I310M-D Irradiator Dimensions3. Air pressure measured at lamp inlet 695Pa (2.

Página 41 - Power Supply Programming

Installation, Operation, and Maintenance Manual # 509252 Rev R 135Figure 55. I310MB/I310MB-D Irradiator DimensionsNotes:1. Dimensions in mm (in)2. Ai

Página 42 - ASSY P/N 32755X

Outline Drawings136 F300S/F300SQ Ultraviolet Lamp SystemFigure 56. I311M/I311M-D Irradiator DimensionsOptimum substratelocation for focusingUV to maxi

Página 43 - 1, 2, and 3

Installation, Operation, and Maintenance Manual # 509252 Rev R 137Figure 57. RF-1 RF Detector Dimensions

Página 44 - Programming

Outline Drawings138 F300S/F300SQ Ultraviolet Lamp System

Página 45 - Remote Inputs

Installation, Operation, and Maintenance Manual # 509252 Rev R 139Appendix D. Lamp System Maintenance LogTable 31 gives an example of a Fusion UV Sy

Página 46 - Output Ports (J105B)

14 F300S/F300SQ Ultraviolet Lamp SystemCAUTION: Ultraviolet RadiationThis icon identifies instances where damaging levels of ultraviolet radiation may

Página 47 - Alternate Function for K5

Lamp System Maintenance Log140 F300S/F300SQ Ultraviolet Lamp System

Página 48 - “Operation” of this manual

Installation, Operation, and Maintenance Manual # 509252 Rev R 141Appendix E. Replacement PartsTable 32 lists the various accessory replacement part

Página 49 - Connections

Replacement Parts142 F300S/F300SQ Ultraviolet Lamp SystemI300M/I310M Irradiator Parts ListTable 33 lists the various replacement parts available for F

Página 50 - Power Source

Installation, Operation, and Maintenance Manual # 509252 Rev R 143I300M/I310M Irradiator Parts ListKit, reflector assembly, I300M, R500 (includes mai

Página 51 - High Voltage Transformer Taps

Replacement Parts144 F300S/F300SQ Ultraviolet Lamp SystemP300M/P300MT Power Supply Parts ListTable 34 lists the various replacement parts available fo

Página 52

Installation, Operation, and Maintenance Manual # 509252 Rev R 145P300M/P300MT Power Supply Parts ListHV transformer, 230V, 50/60 Hz T101, T102 34137

Página 53 - Installation Instructions

Replacement Parts146 F300S/F300SQ Ultraviolet Lamp SystemP300MQ Quick Restart Option Parts ListTable 35 lists the various replacement parts available

Página 54 - Top Vi ew

Installation, Operation, and Maintenance Manual # 509252 Rev R 147K300 Blower Assembly Parts ListK300 Blower Assembly Parts List Table 36. K300 Blowe

Página 55 - Chapter 4. Operation

Replacement Parts148 F300S/F300SQ Ultraviolet Lamp System

Página 56 - Off/Reset Control

Installation, Operation, and Maintenance Manual # 509252 Rev R 149Appendix F. Ignitor BulbNOTE: This appendix applies to lamps manufactured before J

Página 57 - Operating the System

Installation, Operation, and Maintenance Manual # 509252 Rev R 15System DescriptionThe Fusion Ultraviolet Lamp System has been designed specifically

Página 58

Ignitor Bulb150 F300S/F300SQ Ultraviolet Lamp SystemIgnitor Bulb Removal/Replacement1. Replace the ignitor bulb only if the lamp does not start consis

Página 59 - Remote Operation

Installation, Operation, and Maintenance Manual # 509252 Rev R 151Ignitor Bulb Removal/Replacement2. Remove the irradiator housing as described in Ch

Página 60 - Quick Restart Option (QRO)

Ignitor Bulb152 F300S/F300SQ Ultraviolet Lamp System

Página 61

Installation, Operation, and Maintenance Manual # 509252 Rev R 153Appendix G. SchematicsThe following schematics are located within the F300 folder

Página 62

Schematics154 F300S/F300SQ Ultraviolet Lamp System

Página 63 - Operation

16 F300S/F300SQ Ultraviolet Lamp SystemFigure 1. F300S/F300SQ Lamp SystemThe F300S/F300SQ Fusion UV Lamp System (Figure 1) is modular, consisting of i

Página 64

Installation, Operation, and Maintenance Manual # 509252 Rev R 17Electrical inputs to the lamp module are provided by a high voltage/control cable wi

Página 65 - Chapter 5. Troubleshooting

18 F300S/F300SQ Ultraviolet Lamp SystemCoolingProper operation of the lamp requires adequate cooling of the magnetron and the bulb. (See Appendix C, p

Página 66 - Fault Indicators

Installation, Operation, and Maintenance Manual # 509252 Rev R 19The following table lists the various irradiator models manufactured by Fusion UV Sy

Página 68

20 F300S/F300SQ Ultraviolet Lamp SystemMountingThe lamps can be mounted over a moving substrate or web, supported by the bottom rails. The lamps shoul

Página 69

Installation, Operation, and Maintenance Manual # 509252 Rev R 21Figure 4. P300M Front PanelWarranty PolicyItems manufactured by Fusion UV Systems In

Página 70

22 F300S/F300SQ Ultraviolet Lamp SystemNOTE: Any repairs or alterations, including the use of non-Fusion UV Systems (Fusion) parts, made by the user o

Página 71

Installation, Operation, and Maintenance Manual # 509252 Rev R 23IrradiatorsIrradiators should be returned in their original packaging. If this is no

Página 72

24 F300S/F300SQ Ultraviolet Lamp System

Página 73

Installation, Operation, and Maintenance Manual # 509252 Rev R 25Chapter 1. SafetyFusion UV Systems’ Ultraviolet (UV) Lamp Systems have been designe

Página 74

26 F300S/F300SQ Ultraviolet Lamp SystemUltraviolet RadiationThere are no present U.S. government standards on worker exposure to ultraviolet light. Ho

Página 75

Installation, Operation, and Maintenance Manual # 509252 Rev R 27Personnel Effects of Microwave RadiationOSHA (U.S. Department of Labor, Occupational

Página 76

28 F300S/F300SQ Ultraviolet Lamp SystemOzoneThe Fusion UV Lamp System makes less ozone than a conventional arc lamp. For example, a pair of lamps runn

Página 77

Installation, Operation, and Maintenance Manual # 509252 Rev R 29High VoltageInsulated electrical cables carry power at 3900 Volts from the power sup

Página 78

F300S/F300SQ Ultraviolet Lamp SystemInstallation, Operation, and MaintenanceManual No. 509252 Rev R 3/04Applies to systems using P300M/P300MQ/P300MT p

Página 79 - Chapter 6. Maintenance

30 F300S/F300SQ Ultraviolet Lamp System

Página 80 - Screen Cleaning

Installation, Operation, and Maintenance Manual # 509252 Rev R 31Chapter 2. Mechanical InstallationMechanical Installation ChecklistBefore operating

Página 81

32 F300S/F300SQ Ultraviolet Lamp SystemPreliminary unpacking and inspection should be completed immediately on receipt of equipment to allow time for

Página 82 - Reflector Removal/Replacement

Installation, Operation, and Maintenance Manual # 509252 Rev R 33Irradiator MountingThe irradiator mounting structure must also provide UV shielding

Página 83

34 F300S/F300SQ Ultraviolet Lamp SystemLamps Mounted in Opposing ConfigurationFigure 6. Lamps in Opposing ConfigurationUV Light ShieldingAdequate ligh

Página 84

Installation, Operation, and Maintenance Manual # 509252 Rev R 35The louvers which allow the flow of cooling air away from the irradiator must be of

Página 85

36 F300S/F300SQ Ultraviolet Lamp SystemRemote BlowersAn optional remote blower package is available from Fusion UV Systems. The package includes an ai

Página 86

Installation, Operation, and Maintenance Manual # 509252 Rev R 37Figure 8. Quartz Plates - Example Mounting DesignQuartz platemounting structureIrrad

Página 87

38 F300S/F300SQ Ultraviolet Lamp System

Página 88

Installation, Operation, and Maintenance Manual # 509252 Rev R 39Chapter 3. Electrical SystemThis chapter discusses the electrical installation and

Página 90

40 F300S/F300SQ Ultraviolet Lamp SystemInterconnect CablesThe F300S/F300SQ interconnect cables and connector contact kits are listed in Appendix B, “C

Página 91 - I310M/I311M Irradiator

Installation, Operation, and Maintenance Manual # 509252 Rev R 411. Disassemble the strain relief housing by removing the retaining screws and unscre

Página 92 - Reflector Cleaning

42 F300S/F300SQ Ultraviolet Lamp SystemFigure 10. Location of Programming Switch S1 on PWBK1J9J10J8J6J5JP2J7J3J4J1J2J14J15J16J11K3K4K5K2TP1TP2DS1S1S2S

Página 93

Installation, Operation, and Maintenance Manual # 509252 Rev R 43Figure 11. Table A: Programming Switch S1Single Unit Programming and ConnectionsThe

Página 94

44 F300S/F300SQ Ultraviolet Lamp SystemFigure 12. F300/F300SQ Single-unit InstallationProgrammingSelect one unit as the Master. Set S1-1, 1-2, 1-3, an

Página 95

Installation, Operation, and Maintenance Manual # 509252 Rev R 45Input/Output ConnectionsThe P300M/P300MQ/P300MT has three customer use interlock inp

Página 96

46 F300S/F300SQ Ultraviolet Lamp SystemNOTE: A dry contact (such as a relay contact or a PLC containing a relay contact) with gold contact material s

Página 97

Installation, Operation, and Maintenance Manual # 509252 Rev R 47NOTE: When using circuit currents for K1-K5 below 10mA, contact Fusion UV Systems Cu

Página 98

48 F300S/F300SQ Ultraviolet Lamp SystemMultiple-Unit Programming and ConnectionsProgramming and connections for multiple-unit systems are summarized i

Página 99 - (short) Gasket

Installation, Operation, and Maintenance Manual # 509252 Rev R 49ProgrammingRefer to Figure 11 for programming switch S1 settings and set programming

Página 100

Installation, Operation, and Maintenance Manual # 509252 Rev R 5Table Of ContentsIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 101

50 F300S/F300SQ Ultraviolet Lamp SystemPower Source NOTE: If a line voltage greater than 230V and a frequency of 50 Hz is used, see the “F300S Relay C

Página 102

Installation, Operation, and Maintenance Manual # 509252 Rev R 51North American Applications: 3x12 AWG UL listedInternational Applications: 3x2.5 mm2

Página 103

52 F300S/F300SQ Ultraviolet Lamp SystemQRO Transformer Taps (FOR QRO only)When the Quick Restart Option is installed, the QRO transformers must be tap

Página 104 - Magnetron Removal/Replacement

Installation, Operation, and Maintenance Manual # 509252 Rev R 53F300S Relay Coil Resistor Assembly InstallationThe relay coil resistor assembly must

Página 105 - Air Pressure Verification

54 F300S/F300SQ Ultraviolet Lamp SystemFigure 15. K101 and K102 on P300M/P300MQTB1C101CB1ACB1BC102TB1DB1DB2T103L101T102 T101B101J101C103S1S2S3Top Vi

Página 106 - P300M/P300MQ Power Supply

Installation, Operation, and Maintenance Manual # 509252 Rev R 55Chapter 4. OperationSystem Operation ControlsThe lamp system is operated from the c

Página 107 - Test Point Voltages

56 F300S/F300SQ Ultraviolet Lamp System• Bulb producing insufficient output to activate the photocellFor proper initial ignition, the recommended “MIN

Página 108 - Diode Test

Installation, Operation, and Maintenance Manual # 509252 Rev R 573. Press the LAMP ON switch: the green LAMP ON indicator blinks, then stays lit.4. C

Página 109

58 F300S/F300SQ Ultraviolet Lamp System4. The LAMP CONTROL switches on the Master may now be used to activate all units in the system at the same time

Página 110 - Capacitor Test

Installation, Operation, and Maintenance Manual # 509252 Rev R 59NOTE: Times indicated are approximate and will vary. The exact interval is determine

Página 111 - Side View

6 F300S/F300SQ Ultraviolet Lamp SystemTemperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28High Voltage . .

Página 112 - P300MT Power Supply

60 F300S/F300SQ Ultraviolet Lamp System2. Turn the Master POWER switch ON and press the LAMP ON switch.3. The system will now operate from remote swit

Página 113

Installation, Operation, and Maintenance Manual # 509252 Rev R 61The QRO consists of a high-voltage, low-current power supply section located in the

Página 114

62 F300S/F300SQ Ultraviolet Lamp SystemFigure 16. Restart Time Versus QRO State Duration, D-bulbFigure 17. Restart Time Versus QRO State Duration, H-b

Página 115

Installation, Operation, and Maintenance Manual # 509252 Rev R 63Figure 18. Restart Time Versus QRO State Duration, V-bulbElectrical Installation and

Página 116 - T102 Black/White Red/White

64 F300S/F300SQ Ultraviolet Lamp System

Página 117 - To p Vi e w

Installation, Operation, and Maintenance Manual # 509252 Rev R 65Chapter 5. TroubleshootingBasic ChecksCheck that input power is connected properly.

Página 118 - Motor Replacement

66 F300S/F300SQ Ultraviolet Lamp SystemSafety Interlock TestsThe fault indicators, RF detector, and external interlocks should be tested at regular in

Página 119 - Figure 48. Blower Components

Installation, Operation, and Maintenance Manual # 509252 Rev R 67System FaultsThe bottom three LEDs indicate system faults. These faults always shut

Página 120 - J11-3 White

68 F300S/F300SQ Ultraviolet Lamp SystemTable 18, “Troubleshooting/Fault Diagnosis,” on page 69 covers miscellaneous faults and malfunctions.NOTE: The

Página 121 - Appendix A. Specifications

Installation, Operation, and Maintenance Manual # 509252 Rev R 69Table 18. Troubleshooting/Fault DiagnosisOperationSignal/Other SymptomsPossible Caus

Página 122 - Specifications

Installation, Operation, and Maintenance Manual # 509252 Rev R 7Power Source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 123 - Irradiators

70 F300S/F300SQ Ultraviolet Lamp SystemLamp control at OFF, or from OFF to STANDBYEXT INTLK indicator lightsOpen control input. A jumper or an externa

Página 124 - RF Detector

Installation, Operation, and Maintenance Manual # 509252 Rev R 71Switch from OFF to STANDBYBLWR PRESSURE indicator lightsSingle-phase voltage missing

Página 125 - System Agency Approvals

72 F300S/F300SQ Ultraviolet Lamp SystemSwitch from OFF to STANDBY or from STANDBY to ONPS TEMP indicator lightsPower supply fan inoperativeRepair or r

Página 126

Installation, Operation, and Maintenance Manual # 509252 Rev R 73Switch from STANDBY to ONLAMP OUT indicator lights after 8 seconds;Lamp bulb does no

Página 127 - Interconnect Cables

74 F300S/F300SQ Ultraviolet Lamp SystemSwitch from STANDBY to ON(continued)LAMP OUT indicator lights after 8 seconds;Lamp bulb does not light (continu

Página 128 - System Connector Contact Kits

Installation, Operation, and Maintenance Manual # 509252 Rev R 75Switch from STANDBY to ON (continued)LAMP OUT indicator lights after 8 seconds; Lamp

Página 129 - Appendix C. Outline Drawings

76 F300S/F300SQ Ultraviolet Lamp SystemSwitch from STANDBY to ON(continued)PWR IMBAL indicator lightsPower Supply Usually, a diode or capacitor failur

Página 130 - Outline Drawings

Installation, Operation, and Maintenance Manual # 509252 Rev R 77Lamp Control at LAMP ONLAMP OUT indicator does not light, or UV lamp does not lightC

Página 131

78 F300S/F300SQ Ultraviolet Lamp System

Página 132

Installation, Operation, and Maintenance Manual # 509252 Rev R 79Chapter 6. MaintenanceThis chapter provides maintenance procedures for the I300M ir

Página 133 - 1. Dimensions in mm (in)

8 F300S/F300SQ Ultraviolet Lamp SystemBulb, Screen, and Reflector Maintenance . . . . . . . . . . . . . . . . 79Cleaning Guidelines . . . . . . .

Página 134

80 F300S/F300SQ Ultraviolet Lamp SystemIf cleaning reflectors while assembled in the irradiator, drying with compressed air is NOT recommended because

Página 135

Installation, Operation, and Maintenance Manual # 509252 Rev R 811. Refer to Figure 19. Loosen the four M3 screen retaining screws three turns each.

Página 136

82 F300S/F300SQ Ultraviolet Lamp SystemCAUTION: Do not apply bending force to the lamp bulb. Do not touch the bulb with bare fingers or allow it to co

Página 137

Installation, Operation, and Maintenance Manual # 509252 Rev R 833. Referring to Figure 23, remove and discard the two end reflectors and the gaskets

Página 138

84 F300S/F300SQ Ultraviolet Lamp System7. Align the reflector squarely over the opening. With gentle pressure and a rocking motion, slide the reflecto

Página 139 - Lamp System Maintenance Log

Installation, Operation, and Maintenance Manual # 509252 Rev R 85CAUTION: Do not use the flathead screws to pull the reflector into place. Excessive

Página 140

86 F300S/F300SQ Ultraviolet Lamp System11. Replace the screen assembly. After replacing the screen assembly, refer to Figure 26; hand-tighten the four

Página 141

Installation, Operation, and Maintenance Manual # 509252 Rev R 87Figure 27. I300M/I301M Irradiator Component LocationDirect View Photoresistor Remova

Página 142 - Replacement Parts

88 F300S/F300SQ Ultraviolet Lamp System5. Remove and discard the PWB and inspect the UV filter lens for damage.6. Replace the photoresistor and UV fil

Página 143

Installation, Operation, and Maintenance Manual # 509252 Rev R 895. Reconnect the filament transformer wires to the magnetron and tighten the termina

Página 144

Installation, Operation, and Maintenance Manual # 509252 Rev R 9Control Card Removal/Replacement . . . . . . . . . . . . . . . 107Diode Test . . .

Página 145

90 F300S/F300SQ Ultraviolet Lamp SystemAir Pressure VerificationTo test air pressure inside the irradiator, remove one cover plate screw and, using a

Página 146 - P300MQ Quick Restart Option

Installation, Operation, and Maintenance Manual # 509252 Rev R 91Air Pressure Switch Replacement1. Remove the irradiator cover.2. Pull the silicone t

Página 147

92 F300S/F300SQ Ultraviolet Lamp SystemBulb CleaningHandle bulbs with a lint-free cloth or tissue taking care not to leave fingerprints.Baked-on mater

Página 148

Installation, Operation, and Maintenance Manual # 509252 Rev R 93Screen Assembly Removal/Replacement1. Refer to Figure 31. Loosen the four M3 screen

Página 149 - Appendix F. Ignitor Bulb

94 F300S/F300SQ Ultraviolet Lamp SystemCAUTION: Do not apply bending force to lamp bulb. Do not touch the bulb with bare fingers or allow it to contac

Página 150 - Ignitor Bulb

Installation, Operation, and Maintenance Manual # 509252 Rev R 952. Remove the six flat head screws and lift the reflector out. Examine the cross-gui

Página 151

96 F300S/F300SQ Ultraviolet Lamp SystemFigure 34. Gasket Installation (I330M/I311M)4. Insert both end reflectors, ensuring that they both seat fully a

Página 152

Installation, Operation, and Maintenance Manual # 509252 Rev R 97Figure 35. Correct Reflector Alignment (I310M/I311M)7. Align the reflector squarely

Página 153 - Appendix G. Schematics

98 F300S/F300SQ Ultraviolet Lamp SystemFigure 36. Reflector Screw Tightening Sequence (I310M/I311M)8. When the reflector is properly installed, the fa

Página 154 - Schematics

Installation, Operation, and Maintenance Manual # 509252 Rev R 99Replacing the RF Gasket Assembly1. If you detect evidence of arcing on the back of t